BL(T) series stainless steel multi-stage centrifugal pump (afterwards called pump)boasts characters of high efficiency, low noise, steady operation, etc.The pump set adopts the non-self-priming vertical multi-stage structure, which makes a compact whole,its installation easy, its operation and maintenance convenient.
Opskrba vodom |
BL |
BLT |
Filtracija i transfer na vodovodu |
â— |
â— |
Distribucija iz vodovoda |
â— |
â— |
Pressureboosting in mains |
â— |
â— |
Povećanje pritiska u visokim zgradama, hotelima, itd. |
â— |
â— |
Povišenje pritiska za industrijsku vodu |
â— |
â— |
Industrija |
|
|
Pressure boosting |
|
|
Sistemi procesne vode |
â— |
â— |
Washing and cleaning systems |
â— |
â— |
Tuneli za pranje vozila |
â— |
â— |
Sistemi za gašenje požara |
â— |
â— |
Prenos tečnosti |
|
|
Cooling and air-conditioning systems(refrigerants) |
â— |
â— |
Sistemi napajanja i kondenzata kotla |
â— |
â— |
Alatni strojevi (rashladna maziva) \ t |
â— |
â— |
Aquafarming |
â— |
â— |
Transfer |
|
|
Ulje i alkohol |
â— |
â— |
Glycol and coolants |
â— |
â— |
Obrada vode |
|
|
Ultra-filtracioni sistemi |
â— |
â— ‹ |
Reverse osmosis systems |
â— |
â— ‹ |
Softening, ionising, demineralizing systems |
â— |
â— ‹ |
Distillation sys tems |
â— |
â— ‹ |
Separators |
â— |
â— ‹ |
Kupanje za kupanje |
â— |
â— |
lrrigation |
|
|
Field irrigation(flooding) |
â— |
â— |
Sprinkler irrigation |
â— |
â— |
Drip-feed irrigation |
â— |
â— |
Standard energetske efikasnosti (IEC60034)
Izračun minimalnog ulaznog pritiska
Ako je pritisak u pumpi niži od pritiska pare medija, doći će do kavitacije, što će utjecati na performanse pumpe. Da bi se izbjegla kavitacija i osigurao minimalni tlak na ulazu pumpe, maksimalna usisna visina treba izračunati na sljedeći način:
H = Pbx10.2-NPSH-Hf-hv-Hs
Pb: Atmospheric pressure, bar (In close pipeline system, it can be considered as the system pressure );
NPSH: Net positive suction head, m (Value at maximum flow of Q-NPSH curve);
Hf: Suction pipe line loss (Value at maximum flow of corresponding pipeline);
Hv: Srednji pritisak pare, m (Srednji pritisak pare na odgovarajućoj temperaturi, zadani medij je voda, kao što je prikazano na slici 4 desno);
Hs: Sigurnosna granica, m, opća vrijednost je 0,5.
Calculation result: if H is positive, the pump is installed in suction way, otherwise, it is installed in downdraft way.
Napomena: Nije potrebno vršiti izračunavanje iznad općih uvjeta. Samo kada koristimo pumpu u sledećim situacijama moramo izračunati H:
1. Medium temperature is high;
2. brzina protoka je veća od nominalne vrijednosti;
3.Suction head is big or inlet pipeline is long;
4.Sistemski pritisak je mali;
5.Ulazno stanje je loše.
Izbor pumpi
Izbor pumpi treba da se zasniva na:
Radna tačka pumpe.
Podaci o dimenzijama kao što je gubitak pritiska kao rezultat razlika u visini, gubitak trenja u cjevovodu,
Pump efficiency etc.
Materijali pumpe
Pump connections
Commonly used mechanical seal configuration tables
1. Točka rada pumpe:
Iz radne tačke moguće je izabrati pumpu na bazi krive karte prikazane u "performansama / tehničkim" oznakama. podaci.2. Dimensional data:
When sizing a pump the following must be taken into accounting: •Required flow and pressure at the draw-off point. •Pressure loss as a result of height differences. •Friction loss in the pipework(Hf) (Refer to Fig.1) It may. •Best efficiency at the estimated duty point. •NPSH value. •For calculation of the NPSH value, see corresponding curves chart.3. Efikasnost pumpe:
Before determining the best efficiency point, the operation pattern of the pump needs to be identified. If the pump expected to operate as the same duty point, then select a BL pump which is operating at a duty point corresponding with the best efficiency of the pump.Pošto je pumpa dimenzionirana na osnovu najvećeg mogućeg protoka, važno je uvek imati radnu tačku desno na krivoj efikasnosti (eta) kako bi se održala visoka efikasnost kada se protok smanji.
4. Pump material:
Izbor priključka pumpe zavisi od nazivnog pritiska i rada cijevi. pumpa nudi širok spektar nepovezanih priključaka kao što su:
5. Commonly used mechanical seal configuration tables
Application Field | Vrsta brtve vratila | Materijal brtve vratila | ||||||||||
Normalno | Poseban | 1 | 2 | 3 |
4
5
|
Type key | ||||||
Rotirajući dio | Kod | Stationary part | Kod | Elastomers | Kod | Compression spring | Collor | Kod | ||||
0℃ to +90℃ clean water | â— | Grafit | A | SiC | S | FPM | F | SUS304 | C | ASFC | ||
0℃ to +90℃ clean water | â— | toalet | W | Grafit | A | FPM | F | SUS304 | C | WAFC | ||
+ 90 „do + 120â otpornost na koroziju | â— | SiC | S | SiC | S | EPDM | E | SUS304 | C | SSEC | ||
do 0 „ | â— | toalet | W | toalet | W | EPDM | E | SUS304 | C | WWEC |
Tip mehaničke brtve | Pump model | d1 | d2 | h |
NJK | BL(T)2/4 | 12 | 12 | 55 |
BL (T) 8/12/16/20 | 16 | 16 | 57.5 | |
BL (T) 32/45/60/90 | 22 | 22 | 72 | |
NDA | BW(J)2/4 | 12.7 | 16 | 32 |
BW(J)8/16 | 17.4 | 20 | 33.5 |
Model |
Curve No. |
BL (T) 2,4 |
2 |
BL (T) 8,12,16,20 |
3 |
BL(T)32-2-2~BL(T)32-7 |
1 |
BL (T) 32-8-2 ~ BL (T) 32-12 |
4 |
BL (T) 32-13 ~ BL (T) 32-15-2 |
5 |
BL(T)45-2-2~BL(T)45-6 |
1 |
BL (T) 45-7-2 ~ BL (T) 45-9 |
4 |
BL (T) 45-10-2 ~ BL (T) 45-13-2 |
5 |
BL (T) 64-2-2 ~ BL (T) 64-5-2 |
1 |
BL (T) 64-5-1 ~ BL (T) 64-8 |
4 |
BL(T)90-2-2~BL(T)90-4-2 |
1 |
BL(T)90-4~BL(T)90-6 |
4 |
BL(T)120,150 |
6 |
Granice pritiska i temperature prikazane su na slici 4, tlak i temperatura moraju biti prikazani na slici. 4.
Kada pumpa radi na mjestu gdje je temperatura okoline veća od 40 „ili je visina veća od 1000m, izlazna snaga motora P2 će se smanjiti zbog slabog hlađenja uzrokovanog niskom gustoćom zraka. treba biti opremljen motorom velike snage.
Preporučuje se da se koristi u rasponu dizanja.
Preporučuje se da se koristi u rasponu dizanja.
Preporučuje se da se koristi u rasponu dizanja.
Preporučuje se da se koristi u rasponu dizanja.
Preporučuje se da se koristi u rasponu dizanja.
Preporučuje se da se koristi u rasponu dizanja.
Preporučuje se da se koristi u rasponu dizanja.
Preporučuje se da se koristi u rasponu dizanja.
Preporučuje se da se koristi u rasponu dizanja.
Standardna prirubnica PN25-40 / DN100, na upit.
Preporučuje se da se koristi u rasponu dizanja.
Standardna prirubnica PN25-40 / DN100, na upit.
Preporučuje se da se koristi u rasponu dizanja.
Preporučuje se da se koristi u rasponu dizanja.